5501558354
The previous approval registry used a oneshot channel, so two independent signals decided an approval: the HTTP handler's result (from Sender::send's bool) and the agent loop's allow/deny (from which timeout arm fired). At the 300s boundary these could disagree — a late /approve could see send() return Ok (receiver not yet dropped) and report ok:true to the user, while the timeout's final poll simultaneously fired and denied the tool. The frontend was told "approved" while nothing ran. The mirror case (ok:false but allowed) was impossible, so it never executed an unapproved tool, but the user-facing signal could lie. Replace the channel with a single source of truth: each entry is an AtomicU8 state machine (Pending -> Approved/Denied/TimedOut) plus a Notify. The decision is made by exactly one compare_exchange from Pending — whoever wins (approver or timeout) settles it, everyone else observes a losing CAS and no-ops. resolve() now returns whether *its* CAS won, so /approve tells the frontend the truth; the loop decides purely from the settled atomic. They read the same atomic and cannot disagree. A PendingGuard removes the registry entry on drop (normal completion or aborted/disconnected session), so there is no leak on any path. The callback also emits an approval_resolved SSE event with the final decision so a late click — already told ok:false — can dismiss its modal with the real outcome. Verified with an integration test that races resolve() against a near-zero timeout 5000x and asserts ok==true iff the executed decision is Approved (never a mixed state). Run via tests/ because the in-crate lib test binary is currently blocked by unrelated AppConfig test fixtures in other modules.